Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

Background: UK Biobank is a large prospective study that recruited 500,000 participants aged 40 to 69 years, between 2006-2010.The study has collected (and continues to collect) extensive phenotypic and genomic data about its participants. In order to enhance further the value of the UK Biobank resource, a wide range of biochemistry markers were measured in all participants with an available biological sample. Here, we describe the approaches UK Biobank has taken to minimise error related to sample collection, processing, retrieval and assay measurement. Methods: During routine quality control checks, the laboratory team observed that some assay results were lower than expected for samples acquired during certain time periods. Analyses were undertaken to identify and correct for the unexpected dilution identified during sample processing, and for expected error caused by laboratory drift of assay results. Results: The vast majority (92%) of biochemistry serum assay results were assessed to be not materially affected by dilution, with an estimated difference in concentration of less than 1% (i.e. either lower or higher) than that expected if the sample were unaffected; 8.3% were estimated to be diluted by up to 10%; very few samples appeared to be diluted more than this. Biomarkers measured in urine (creatinine, microalbumin, sodium, potassium) and red blood cells (HbA1c) were not affected. In order to correct for laboratory variation over the assay period, all assay results were adjusted for date of assay, with the exception of those that had a high biological coefficient of variation or evident seasonal variability: vitamin D, lipoprotein (a), gamma glutamyltransferase, C-reactive protein and rheumatoid factor. Conclusions: Rigorous approaches related to sample collection, processing, retrieval, assay measurement and data analysis have been taken to mitigate the impact of both systematic and random variation in epidemiological analyses that use the biochemistry assay data in UK Biobank.

Original publication

DOI

10.12688/wellcomeopenres.16171.1

Type

Journal article

Journal

Wellcome open research

Publication Date

01/2020

Volume

5

Addresses

Clinical Trial Service Unit and Epidemiological Studies Unit, Nuffield Department of Population Health, University of Oxford, OXFORD, Oxon, OX3 7LF, UK.