Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

ImportanceThere is a need for better arrhythmic risk stratification in nonischemic dilated cardiomyopathy (DCM). Titin-truncating variants (TTNtvs) in the TTN gene are the most common genetic cause of DCM and may be associated with higher risk of arrhythmias in patients with DCM.ObjectiveTo determine if TTNtv status is associated with the development of life-threatening ventricular arrhythmia and new persistent atrial fibrillation in patients with DCM and implanted cardioverter defibrillator (ICD) or cardiac resynchronization therapy defibrillator (CRT-D) devices.Design, setting, and participantsThis retrospective, multicenter cohort study recruited 148 patients with or without TTNtvs who had nonischemic DCM and ICD or CRT-D devices from secondary and tertiary cardiology clinics in the United Kingdom from February 1, 2011, to June 30, 2016, with a median (interquartile range) follow-up of 4.2 (2.1-6.5) years. Exclusion criteria were ischemic cardiomyopathy, primary valve disease, congenital heart disease, or a known or likely pathogenic variant in the lamin A/C gene. Analyses were performed February 1, 2017, to May 31, 2017.Main outcome and measuresThe primary outcome was time to first device-treated ventricular tachycardia of more than 200 beats/min or first device-treated ventricular fibrillation. Secondary outcome measures included time to first development of persistent atrial fibrillation.ResultsOf 148 patients recruited, 117 adult patients with nonischemic DCM and an ICD or CRT-D device (mean [SD] age, 56.9 [12.5] years; 76 [65.0%] men; 106 patients [90.6%] with primary prevention indications) were included. Having a TTNtv was associated with a higher risk of receiving appropriate ICD therapy (shock or antitachycardia pacing) for ventricular tachycardia or fibrillation (hazard ratio [HR], 4.9; 95% CI, 2.2-10.7; P Conclusions and relevanceHaving a TTNtv was an important risk factor for clinically significant arrhythmia in patients with DCM and ICD or CRT-D devices. Having a TTNtv, especially in combination with midwall fibrosis confirmed with cardiovascular magnetic resonance imaging, may provide a risk stratification approach for evaluating the need for ICD therapy in patients with DCM. This hypothesis should be tested in larger studies.

Original publication

DOI

10.1001/jamanetworkopen.2019.6520

Type

Journal article

Journal

JAMA network open

Publication Date

06/2019

Volume

2

Addresses

National Heart and Lung Institute, Imperial College London, London, United Kingdom.

Keywords

Humans, Cardiomyopathy, Dilated, Retrospective Studies, Defibrillators, Implantable, Phenotype, Adult, Aged, Middle Aged, Female, Male, Arrhythmias, Cardiac, Genetic Variation, Connectin